Sub-Basin Window

Aus TALSIM Docs
Sprachen:

The data sheet for the catchment area can be opened by double clicking on the element symbol in the system plan Datei:System element001.png or by right clicking -> Data sheet.

It has the three tabs Properties, Simulation Settings and Sequence Assignment. In the upper part of the window there are also three buttons for saving Datei:Button_speichern.PNG, for applying the parameters and settings from catchment area elements in the same database (i.e. also from other variants and projects) Datei:Button_Werte_übernehmen.PNG and for closing the window. It is important to know that the catchment area window also saves automatically when closing.


Datei:Einzugsgebietsfenster_leer_EN.png


Properties

In the Properties tab, general parameters and parameters of the catchment area for topography, surface runoff retention and measures in the catchment area are entered, and the calculation method for determining the runoff-effective fraction of precipitation is selected and the required parameters are entered.


Topography

Einzugsgebietsfenster Topographie EN.PNG

The data to be entered in the Topography section is normally determined from a GIS. The area of the catchment area is decisive for the amount of runoff that is generated in this catchment area, because the precipitation as precipitation height is included in the NA calculation and is therefore still scaled with the area.

The degree of sealing determines the proportion of sealed area in the total area and describes the proportion that runs off as urban surface runoff. The urban surface runoff is separated from the remaining natural surface runoff calculated and retained in a separate storage cascade. The discharge allocation can also be used to assign it to a different discharge element. The input for longest flow distance and maximum and minimum height are used for the automatic calculation of the retention constants of surface runoff.


Retention-Surface Runoff

Einzugsgebietsfenster Retention Oberflächenabfluss EN.PNG

The parameters for the discharge concentration of the surface discharge are entered in the Retention- Surface Discharge section. Using the button calculate, they can be automatically calculated from the input for topography. Attention: if the checkbox calculate automatically is set, the automatically calculated parameters are always used for the simulation, based on the current input in the topography section. If the retection constants of the surface runoff shall be changed and calibrated, the check mark must be removed first.


Measures in the catchment area

Einzugsgebietsfenster Maßnahmen im EZG EN.PNG

In the Measures in the Catchment Area section, the user can enter the depression losses . Using the button Irrigation he can also define and connect a irrigation scheme.


Calculation

For the calculation of Infiltration or the runoff-effective precipitation, Talsim-NG offers three calculation options, which can be selected in the Calculation Method section.


Runoff curve number

Datei:Einzugsgebietsfenster Berechnungsweise Abflussbeiwert_EN.png

If the discharge coefficient method is selected, a constant discharge coefficient between 0 and 1 can be entered. This determines the amount of precipitation that is discharged after deducting losses.


SCS-CN Method

Datei:Einzugsgebietsfenster_Berechnungsweise_SCS_CN_Methode_EN.png

If the SCS-CN method has been selected as the calculation method, the CN value and the 21-day rainfall index can be entered in the lower area. In addition, a check box can be used to activate whether the SCS method is calculated with constant loss.


Extended procedure

Datei:Einzugsgebietsfenster_Berechnungsweise_SCS_CN_Methode_erweitert_EN.png

In the extended procedure, not only the superficial direct runoff is determined, but also a soil moisture simulation is carried out for the infiltrated part and the components interflow and basic runoff are determined. For this purpose, the elementary areas must be created using the corresponding button. For interflow and base discharge the retention constants for the calculation of the discharge concentration are also defined. The initial soil moisture can also be entered (default setting: 100%). If the checkbox Use original soil layers is activated, the soil layers are used as entered by the user. By default, the soil layers are grouped into three internal calculation layers (infiltration layer, rooting layer and transport layer).


Soil Moisture

Datei:Einzugsgebietsfenster_Berechnungsweise_Bodenfeuchte_EN.png

The calculation option soil moisture simulation is the calculation option that requires the input of most parameters. The catchment area is divided into individual elementary areas (hydrologic response units) using the elementary areas (EFL) button. The catchment area window provides the option to assign a uniform slope to all elementary surfaces.

For interflow and base discharge the retention constants for the calculation of discharge concentration are defined.

If the calculation of the deep interflow and/or the deep base discharge is also activated via checkboxes, the retention constants must also be entered for these two discharge components, as well as the desired division ratio for the base discharge into base discharge and deep base discharge. The initial soil moisture can also be entered (default setting: 100%).

If the checkbox Use original soil layers in the calculation area is activated, the soil layers will be used as entered by the user. By default, the soil layers are grouped into three internal calculation layers (infiltration layer, rooting layer and transport layer).


Simulation Settings

Einzugsgebietsfenster Simulationseinstellungen EN.PNG

The Simulation Settings tab is used to define the loads on the catchment area and to select the calculation type for the snow calculation.

The selection of the time series is done with the button Selection Datei:Button_Zeitreihe_zuordnen.png. The button Display Datei:Button_Zeitreihe_anzeigen.png opens a window with the time series graphics.

constant hydrograph can be connected via their respective selection menus and can be deleted with the DELETE-key. By clicking the button Show chart File:Button_Ganglinie_ anzeigen.png, the hydrograph window opens, where the chart can be edited directly. It is important to note that the hydrograph can also be connected at other places in the model and that the changes are valid everywhere. If you want to modify a chart only for the current catchment area, a copy has to be created and connected before.


Precipitation

Precipitation can be directly connected as a time series and can be scaled by a factor if necessary. If no long-term simulation but a short-term forecast with model rain is to be calculated, the settings are controlled directly via the short-term forecast.


Temperature

The temperature can be entered either as a time series or as an average temperature, if necessary scaled with an annual and/or daily variation.


Evaporation

For the evaporation there is the possibility to connect a time series, to define a yearly evaporation or to use the values from a previously created evaporation calculation.


Base discharge: mean value

A basic discharge can be specified as a mean donation and, if necessary, scaled with a yearly flow.

For soil moisture calculation, this value determines the start content (recalculated) for the basic runoff storage tank. From the l/s km² given here a volume is recalculated, which together with the retention constant of the base runoff gives this value for the base runoff at the beginning of the simulation.


Snow

Sequence assignment

Einzugsgebietsfenster Ablaufzuordnung.PNG

If the catchment element has more than one runoff element, the different runoff components can be sent to different runoff elements in the Runoff Assignment tab. By default, the entire drain goes to the first drain. Using drag&drop, the drain components shown on the left can be dragged to the drains on the right of the screen to make or break the connection. By clicking on the drain components, the respective connection to the drain is marked red. Clicking on the drains will mark the connections of all inflowing drain components.