Aus TALSIM Docs
Version vom 26. November 2020, 15:26 Uhr von Ferrao (Diskussion | Beiträge) (Die Seite wurde neu angelegt: „:thumb|left|Figure 14: Example functions for linking a system state with an releaseMemory B takes 100% of the output of A as long as…“)
(Unterschied) ← Nächstältere Version | Aktuelle Version (Unterschied) | Nächstjüngere Version → (Unterschied)
Datei:Theory Abb14.png
Figure 14: Example functions for linking a system state with an release
Memory B takes 100% of the output of A as long as its filling does not reach 70% of the maximum content. Furthermore, it is undesirable to receive additional water for flood protection reasons. The scaling factor decreases from 70% filling to zero. Storage tank A can transfer water to B with an increasing tendency from a filling level above 50%. The actual transfer, however, only results from the interaction of both functions, taking into account the current tank filling of B and the scaling derived from it.