ERROR-File

During each simulation the data set is temporarily stored under D:\Talsim-NG\Client\TalsimNG\Simulation. They are deleted again after closing TALSIM NG. If the simulation is aborted, an ASCII file *.ERR is created which contains a short description of the cause of the abort.

Furthermore, a more detailed description of the cause can be read by right-clicking on the simulation under the Error message button.


Cause for termination of the simulation

400px
  • Simulation period is outside the date of the time series
  • In the state groups the calculation order was not updated when inserting new control groups
  • Overflow of storage elements, due to too large inflow or too small outflow. Inserting an emergency overflow is necessary.
  • Error in the rules and controls


Copy / export variants

If variants are not copied or exported, it is because there is no active simulation. The reason could be the deletion of the active simulation. For this reason you have to right-click on the simulation -> Activate simulation in the variant to be copied.


Error messages in system editor

"Die maximale Anzahl von <XXX> oder Systemelementen ist bereits vorhanden!"

Ursache: Die maximale Anzahl von Systemelementen eines bestimmten Typs ist bereits erreicht.

Lösung: Im Installationsverzeichnis die Datei \Client\TalsimNG\Definition\TalsimDef.mdb in Microsoft Access öffnen, darin die Tabelle "SystemobjektTyp" öffnen, und dort den Wert im Feld "MaximaleAnzahl" für den gewünschten Typ anpassen. Die Datenbank wieder schließen und Talsim neu starten, damit die Änderungen wirksam werden.