Translations:Betriebsregeltypen/39/en
Version vom 30. August 2021, 11:27 Uhr von Haghani (Diskussion | Beiträge)
- Dependency:
- There is a direct dependency between the discharge from the storage and the current inflow to the storage. Similar to the pool-based operating plan, there is also an adaptation to different inflow situations. This is done to prevent depletion or overflowing or to obtain a variable discharge regime downstream. However, long-term inflow fluctuations are difficult to detect with this operating rule, since the observations are only carried out as snapshots and not continuously.