Bereich Simulationen/en: Unterschied zwischen den Versionen

Aus TALSIM Docs
(Die Seite wurde neu angelegt: „===Start simulation===“)
(Die Seite wurde neu angelegt: „Selecting the menu item Start Simulation opens a own window in which further simulation settings can be made.“)
Zeile 145: Zeile 145:
===Start simulation===
===Start simulation===


Mit der Auswahl des Menüpunkts Simulation starten öffnet sich ein [[Special:MyLanguage/Fenster Simulation-Wizard|eigenes Fenster]], in dem weitere Simulationseinstellungen vorgenommen werden können.
Selecting the menu item Start Simulation opens a [[Special:MyLanguage/Fenster Simulation-Wizard|own window]] in which further simulation settings can be made.





Version vom 23. Oktober 2020, 15:08 Uhr

Sprachen:

Datei:Benutzeroberfläche00031.png

A simulation is automatically created in the system administration if you create a new variant, a copy or a import. When creating a new variant, an empty simulation is created, whereas when copying and importing a variant, the settings (e.g. simulation period) of the original simulation are taken over. To add a new simulation to an existing simulation in a variant, you can either create a new simulation or you can add an already existing simulation through copy and paste.

With the execution of a simulation calculation, input variables and results are stored in the simulation and can be viewed via load results. It is recommended not to change the project structure when executing several simulations in one variant, but only to change simulation settings or to adjust single parameters or input variables and to document the adjustments.

The following columns are filled for each simulation:

Designation Name of the simulation. It is important to choose a clearly identifiable name e.g. output parameters or changes in the system.
ID Identification number of a simulation. It is recommended to always note the ID for evaluations in order to find the corresponding variant and simulation more quickly for large projects.
Simulated on Date and time on which the simulation was performed.
from Date and time of simulation start
to Date and time of simulation end


Right-click on the simulation name to open the following context menu:

Datei:Kontextmenü_Simulation.png

Create new simulation A new empty and inactive simulation is created.
Cut The selected simulation is cut out and can be inserted in another variant.
Copy The selected simulation is copied and can be pasted in this or any other variant.
Paste After cutting or copying the marked simulation, it is inserted in the marked variant.
Rename The name of the selected simulation can be changed.
Delete The selected simulation is deleted. This operation cannot be undone. Caution: If the activated simulation has been deleted, the variant cannot be copied or exported.
Features A window opens in which the simulation settings can be edited.
Simulation Further submenu items open:
Datei:Kontextmenü_Simulation_Simulation.png Datei:Kontextmenü_Simulation_Anfangsbedingungen.png
Activate simulation The selected simulation becomes the active simulation (Datei: Benutzeroberfläche00029.png). When exporting a variant to the server, the results of the active simulation are used.
Error messages
Simulation Log
Export simulation to server The results of the selected simulation are exported to the server and assigned to a variant.


Create new simulation

A new simulation is created by right-clicking in the Simulations area and selecting Create new simulation from the context menu. In a newly created simulation many settings are still empty, in other settings there are default values. A new simulation gets the default name New Simulation. In order to take over settings directly from other simulations, it is recommended to create this simulation as a new simulation in the corresponding variant via copy and paste.


Activate simulation

An active simulation is crucial when exporting and copying a variant, as the settings and results of the active simulation are used. To activate the simulation, right click on the corresponding simulation and select Activate simulation. The simulation with the red check mark is the active simulation.


Edit simulation

To edit the simulation settings, either right-click on the simulation and select Settings or double-click on the simulation. The following window will open:

Datei:Simulation003.png

Under Simulation you can select the simulation period in the format dd.mm.yyyy hh:mm, as well as the -time step, which is between 1 minute and 1 month. This time step is automatically converted into minutes. For example, if you select a time step of 1 day, it will be set to 1440 minutes.

You can also make entries at Initial conditions and Calculation options. Under Initial Conditions the initial conditions set in the individual system elements can still be globally scaled. Under further options the following windows open in addition to the calculation options, in which you can define specifications for the catchment area, error deviations and result output. For the result output it is important in which resolution you want to have the results. For example, if you calculate on a 2 hour basis, but a result output of 1 day is sufficient, enter 12 for every nth time step in the output. Then only every 24 hours a value will be output, as average of the 12 calculated 2 hour values.

Datei:Simulation004.png Datei:Simulation005.png Datei:Simulation006.png

Under Name you can rename the simulation and add a comment.


Copy simulation

To copy the simulation, either right click on the simulation and select copy or mark the simulation with the left mouse button and press Ctrl+C on the keyboard. The complete settings of the copied simulation are taken over. Results will not be copied. You can paste the copied simulation either in the same or in a different variant. Neither the variant nor the simulation must be active.


Cut simulation

To cut the simulation, either right click on the simulation and select cut or mark the simulation with the left mouse button and press Ctrl+X on the keyboard. The complete simulation will be cut out of the variant and thus deleted in this variant. You can then paste the cut simulation into another variant. Neither the variant nor the simulation must be active.

Caution: If you insert a cut-out simulation with results into another variant, the results may not match the new Vairante, because the variant may have either a different system logic or different input parameters.


Insert simulation

If you have copied or cut a simulation beforehand, you can paste it to the new variant either by right-clicking paste or by using the key combination Ctrl+V. The variant in which you want to insert the new simulation does not have to be active.

Caution: If you insert a cut-out simulation with results into another variant, the results may not match the new Vairante, because the variant may have either a different system logic or different input parameters.


Rename simulation

You can rename the simulation by right-clicking on the simulation and selecting rename or by double-clicking on the simulation with the left mouse button.


Delete simulation

To delete a simulation, right click on the simulation to be deleted and select delete. The simulation and with it all results will be deleted irrevocably.


Export simulation to server

Submenu Simulation

Start simulation

Selecting the menu item Start Simulation opens a own window in which further simulation settings can be made.


Anfangsbedingungen

Speicherstartinhalte

Anfangsbedingungen schreiben/ einlesen

Ergebnisausgabe definieren

Kalibrierung

Fehlermeldungen

Simulations-Log